DNB1Z-63 mini DC circuit breaker Miniature circuit breakers - GRL GRUOP

PV System

DNB1Z-63 mini DC circuit breaker Miniature circuit breakers


Mode: DNB1Z-63

Voltage:1250V

Current:6A,10A,16A,20A,25A,32A,40A,50A,63A

Certificate:CB CE CCC

Standard:IEC 60947-2 GB / T 14048.2

Email: [email protected]

Reference:Basis IEC 60068-2-6

Keyword:DC circuit breaker

DC circuit breaker

Suitable range

The rated working voltage of DNB1Z-63 mini DC circuit breaker can be up to DC 250V ( 1P ) ,DC800V (2P),DC800V ( 3P ) , DC1200V ( 4P ) , There is a special arc extinguishing and current limiting system in the MCB,which can quickly disconnect the fault current of the,DC distribution system .

It can protect important components in the solar power generation system , ensures the operation of the solar photovoltaic power generation system is reliable.

Usage environment

The altitude is lower than 2000 meters . Can be if altitude higher than 2000m .Please contact the manufacturer for other special requirements.
The ambient temperature is -25℃ , and the 24-hour average temperature does not exceed + 35 ℃ ; When the ambient temperature is higher than + 40 ℃ or lower than-25 ℃ , please contact the manufacturer.
The product shall be installed in the waterproof distribution box. DC circuit breaker

Model and Meaning

 DC circuit breaker

Technical Parameter

Entry Name Technical Parameter
Rated insulation voltage ( UI ) 1250V
Rated operating voltage ( UE ) DC ( IP ) : 15V , 60V , 100V , 180V , 250V ; DC ( 2P ) : 125V , 375V, 550V ,600V , 800V

DC(3P) : 750V , 800V ; DC ( 4P ) : 800V ,1000V, 1200V

Rated current of frame 63A
Different currents of the same shell frame 6A,10A,16A,20A,25A,32A,40A,50A,63A
Rated operating short-circuit

breaking capacity ( ICS = ICU )

6KA
Rated operating short-circuit

breaking capacity ( ICS = ICU )

2P 800V \ 4p 1200V 2KA
Mechanical life 20000second
Electrical life 10000second ( Belowdc125V/ 1P , Below DC250V / 2P ) ,1000second ( Other voltage specifications )
Certificate CB CE CCC
Rated impulse withstand voltage Uimp 6KA
Tripping characteristics / tripping type B / C ; Thermal porcelain
Overvoltage level
class of pollution 3
Protection grade IP40 ; Connection port IP20
Damp heat resistance Class 2
Relative humidity ≤95%
Standard IEC 60947-2 GB / T 14048.2
Seismic resistance Basis IEC 60068-2-6
Mechanical shock resistance parameters Basis LEC 60068-2-27
Operating ambient temperature -30℃~70℃
Damp heat resistance Db Class ( Temperature 55℃  6 Cycle )
Storage environment temperature -30℃~70℃
Altitude ≤2000m
Weight 0.12kg/p
enclosure OF / SD / MX / MN / MX + OF
MX control voltage Us DC : 12V , 24V ,220V ; AC : 110V , 220V , 380V

It is recommended that the power supply should not be lower than 75W

Mn rated voltage UN AC220V AC380V

knife switch

Click to view grl group company information>>

Click to view grl fuse link product>>

Click to view grl fuse product>>

leave your question

Get your Comfortable Solution

GRL Electric Co., Ltd. is one of the leading companies in the Middle And High End market of low-voltage electric in China

Need Help With Finding The Right Technical Solution?
GET A QUOTE