Strip Fuse Disconnector DNH18 Series - GRL GRUOP

Fuse Switch Disconnector

DNH18 Series Strip Fuse Disconnector


Strip Fuse Disconnector DNH18 Series integrates the design concept of independent innovation, with a novel appearance and upgraded function.

It has 6 utility model patents and 4 appearance patents, which can provide a more safe and convenient installation and operation mode for cable branch boxes, American box transformers, etc.

  • Add installation positioning block
  • Add protection boss
  • Optimize fusible core installation module
  • Add cooling grooves
  • Add rotating shield
  • Various wiring modes can be selected
  • Integrated transformer design
  • Multiple function modules can be selected
  • Unique logo, more distinctive

Strip Fuse Disconnector DNH18 series

GRL is the ideal fuse switch disconnector manufacturer for you. We have a proud history of crafting top-quality products, and we provide outstanding customer service.

Strip Fuse Disconnector



Strip Fuse Disconnector-2



Fuse Disconnector General Model List

Serial number

Order No Electric current

Adaptation

1

DNH18-160/3L 160A Fixed installation (punching), three-phase synchronous operation, with fuse

2

DNH18-160/311L 160A Hook up installation, with auxiliary contact, three-phase synchronous operation, with fuse

3

DNH18-250/3L 250A Fixed installation (punching), three-phase synchronous operation, with fuse

4

DNH18-250/3S 250A Fixed installation (punching), three-phase independent operation, with fuse

5

DNH18-250/3LD 250A Fixed installation (punching), three-phase synchronous operation, with isolating knife

6

DNH18-250/311L 250A Hook up installation, with auxiliary contact, three-phase synchronous operation, with fuse

7

DNH18-400/3L 400A Fixed installation (punching), three-phase synchronous operation, with fuse
8 DNH18-400/3S 400A Fixed installation (punching), three-phase independent operation, with fuse

9

DNH18-400/3LD 400A A fixed installation (punching), three-phase synchronous operation, with isolating knife

10

DNH18-400/311L 400A Hook up installation, with auxiliary contact, three-phase synchronous operation, with fuse

11

DNH18-630/3L 630A Fixed installation (punching), three-phase synchronous operation, with fuse

12

DNH18-630/3S 630A Fixed installation (punching), three-phase independent operation, with fuse

13

DNH18-630/3LD 630A Fixed installation (punching), three-phase synchronous operation, with isolating knife

14

DNH18-630/311L 630A Hook up installation, with auxiliary contact, three-phase synchronous operation, with fuse

Remarks

1. For other specific order models, please see the explanation of the model of the bar fuse disconnector
  2. If you need other accessories, such as wiring terminals, please check the accessories list of strip fuse disconnector


Fuse Disconnector Technical Parameter


DNN18-160

DNN18-250 DNN18-400

DNN18-630

Electrical parameters

With fuse Rated working voltage Ue V AC

400

AC

500

AC

690

AC

400

AC

500

AC

690

AC

400

AC

500

AC

690

AC

400

AC

500

AC

690

 

 

Rated working current Ie A 160 125 100 250 250 200 400 400 315 630 630

630

   

Agreed heating current

Ith A 160 125 100 250 250 200 400 400 315 630 630

630

   

Service level

    AC-23B AC-23B AC-22B AC-23B AC-22B AC-21B AC-23B AC-22B AC-21B AC-23B AC-22B

AC-21B

   

Rated limiting short-circuit current

Iq kA 50 100 100 50 100 100 50 100 100

50

 

 

Rated insulation voltage Ui V 1000 1000 1000

1000

   

Rated impulse withstand voltage

Uimp kV 8 12 12

12

 

  Rated frequency   Hz 50/60 50/60 50/60

50/60

   

Electric life times

  time 200 200 200

200

 

With isolating knife

Rated working voltage Ue V \ \ AC500 \ \ AC500 \ \ AC500

\

   

Rated working current

Ie A \ \ 250 \ \ 400 \ \ 630 \
   

Agreed heating current

Ith A \ \ 250 \ \ 400 \ \ 630

\

   

Service level

    \ \ AC-23B \ \ AC-23B \ \ AC-23B \

 

  Rated limiting short-circuit current Iq kA \ \ 12 \ \ 12 \ \ 12

\

   

Rated insulation voltage

Ui V \ 100 1000

1000

 

 

Rated impulse withstand voltage Uimp kV \ 12 12

12

   

Rated frequency

  Hz \ 50\60 50\60

50\60

 

  Electric life times   time \ 200 200

200

Fuse

Size (RT16/NT/NH)

GB/T13539.2

IEC 62269-2

    00 1 2

3

 

Working current In A 160 125 100 250 250 200 400 400 315 630 630

500

 

power waste

P W 12 12 12 18 23 32 28 34 45 40 48

60

Mechanism

Mechanical life   time 1400 1400 800 800 1400

800

 

Busbar spacing

  mm 185 185 185

185

Protection grade of mechanism

 Front

 

on   IP20 IP20 IP20

IP20

   

off

  IP30 IP30 IP30

IP30

Other

 

Electronic fuse monitor (EFM)     Can be added Can be added Can be added

Can be added

 

Switch opening and closing signal feedback (microswitch)

    Can be added Can be added Can be added Can be added

Working conditions

 

Ambient air temperature  

-5 ~ +55

 

Rated working system

    Uninterrupted working system
 

Operation mode

   

Handle operation

 

Installation method

   

Vertical installation

 

Altitude

  m

≤ 2000

 

class of pollution

   

3

 

Overvoltage level

Overvoltage level  

 



Strip Fuse Disconnector-3

Click to view grl DNH7-160 product>>



Fuse Disconnector Outline and Installation Dimension (mm)


Strip Fuse Disconnector-4


Strip Fuse Disconnector-5


Strip Fuse Disconnector-6


Strip Fuse Disconnector-7

Click to view grl group company information>>

Click to view grl Fuse Switch Disconnector product>>

Click to view grl fuse product>>

leave your question

Get your Comfortable Solution

GRL Electric Co., Ltd. is one of the leading companies in the Middle And High End market of low-voltage electric in China

Need Help With Finding The Right Technical Solution?
GET A QUOTE