Blog

How to install and maintain surge protective devices?

Surge protective devices are designed to protect electrical equipment from transient over voltages, such as those caused by lightning strikes or power line faults. SPDs quickly divert excessive voltage away from sensitive equipment to the ground, limiting voltage peaks to safe levels and preventing damage.

SPDs are essential in homes, commercial buildings, and industrial facilities, safeguarding computers, communication equipment, and industrial control systems from voltage fluctuations. They are a crucial component in modern electrical installations, ensuring the safe operation of power systems.

Click to view grl surge protective device product>>

surge protectors surge protective device Surge Protective Devices

How Do Surge Protective Devices Work?

Surge protective devices function by diverting excessive voltage away from sensitive equipment and directing it safely to the ground. They are designed to react quickly to transient voltage spikes, clamping the voltage to a safe level before it can cause damage. The primary components of an SPD include Metal Oxide Varistors (MOVs), gas discharge tubes, and avalanche diodes, which absorb and dissipate the excess energy.

How to Install a Surge Protective Device (SPD)?

Installing a Surge Protective Device (SPD) involves a careful and systematic process to ensure it is done safely and correctly.

Tools and Materials Needed:

Screwdriver

Wire stripper

Electrical tape

Appropriate gauge cables

SPD device

Multimeter (for testing)

Mounting bracket or DIN rail (if required)

Safety gloves and goggles

Steps for Installing an SPD

Surge Protective Devices

Here are the steps you need to follow:

1. Determine the Installation Location

Main Distribution Board: SPDs are usually installed at the main distribution board where the power enters the building.

Close to Sensitive Equipment: Alternatively, install the SPD near sensitive equipment that needs protection.

2. Turn Off Power

Safety First: Ensure the power supply to the area where the SPD will be installed is turned off to prevent electrical shock.

3. Mount the SPD

DIN Rail or Panel Mount: Depending on the design of the SPD, secure it to a DIN rail or directly to the panel using screws.

4. Prepare the Cables

Strip the Insulation: Use a wire stripper to remove about 10-15mm of insulation from the ends of the wires that will be connected to the SPD.

5. Connect the Wires

Refer to the SPD’s wiring diagram. Generally, SPDs have terminals for live (L), neutral (N), and ground (PE). Follow these steps for a typical connection:

Live Wire (L): Connect the live (hot) wire to the L terminal of the SPD.

Neutral Wire (N): Connect the neutral wire to the N terminal of the SPD.

Ground Wire (PE): Connect the ground wire to the PE terminal of the SPD.

Ensure all connections are tight and secure to prevent any loose connections that could lead to malfunction or hazards.

6. Double-Check Connections

Before turning the power back on, double-check all connections to ensure they are correct and secure. Properly insulate any exposed wire ends with electrical tape if necessary.

7. Restore Power and Test

Restore Power: Turn the power back on at the main breaker or distribution panel.

Test the SPD: Use a multimeter to check the voltage at the SPD terminals to ensure it is receiving power and functioning correctly. The SPD’s indicator lights (if present) should show normal operation.

8. Regular Maintenance

Regularly inspect the SPD for any signs of wear or damage. Ensure that it remains securely connected and replace it if any faults are detected.

Surge Protective Device

How to Check Surge Protective Devices?

1、Visual Inspection: Check for any physical damage or signs of wear.

2、Status Indicators: Many SPDs come with status indicators that show their operational status.

3、Multimeter Test: Measure the voltage across the SPD terminals to ensure it is within the expected range.

How to Integrate SPDs with Fuse Switch Disconnectors?

1、Placement: SPDs should be placed upstream of the fuse switch disconnectors to protect them from surge events.

2、Coordination: Ensure the SPD’s voltage rating matches the operating voltage of the fuse switch disconnectors.

3、Wiring: Properly wire the SPD and fuse switch disconnectors according to the manufacturer’s instructions to ensure seamless operation and protection.

Incorporating Surge Protective Devices (SPDs) and fuse switch disconnectors into your electrical systems is essential for enhancing both safety and reliability. By understanding how these devices work, how to select the right ones, and the proper methods for installation and maintenance, you can significantly reduce the risk of damage from transient overvoltages.

surge

Need Help With Finding The Right Technical Solution?