Drop Out Fuse Cutout 11Kv 15kv 27kv Customized - GRL GRUOP

Fuse

Drop Out Fuse Cutout 11Kv 15kv 27kv Customized


Rated voltage: 10-15KV

Rated current: 100A, 200A

Breaking current: 8/10 kA

Power frequency withstand voltage (kV): 40kV

Dimensions (cm): 42 x 37 x 13.5esfaw

What is a fuse cutout?

 

A Fuse Cutout is a device used in power distribution systems to protect transformers and power lines from damage caused by short circuits, overloads, or other electrical faults. The Fuse Cutout combines the functions of a fuse and a disconnect switch, allowing it to automatically disconnect the circuit during a fault and quickly restore power by replacing the fuse.

Main Components of a Fuse Cutout:

  1. Fuse: The fuse is the key protective element in the circuit. When the current exceeds a preset value, the fuse melts and breaks the circuit to prevent damage to the equipment or line.
  2. Cutout Body: The cutout body, typically made of insulating material, supports the fuse and provides electrical isolation.
  3. Hinged Movable Arm: When the fuse blows, the hinged arm drops down, physically disconnecting the circuit and alerting personnel that the fuse needs replacement.

How a Fuse Cutout Works:

  1. During normal operation, current flows through the fuse, and the power equipment and lines are energized.
  2. In the event of a short circuit or overload, the current increases, causing the fuse to heat up and melt, breaking the circuit and protecting the downstream equipment.
  3. After the fuse blows, the movable arm drops, providing a visible indication of the open circuit. Maintenance personnel can restore the circuit by replacing the fuse.

HV drop out fuse Customized drop out fuse cutout

Selling points of drop out fuse cutout

1、High mechanical intensity

High mechanical intensity, reliable structure,

provides a guarantee for the safe operation of the line.

2、Good pollution resistance performance

Strong anti-pollution ability, wide range of application

it does not require annual cleaning and maintenance in

polluted Areas.

3、Acid and alkalis resistance

Heat-proof aging and electricity resistance;

Seal well to ensure internal insulation without damping.

4、Good brittle resistance

Strong earthquake resistance, Avoid fracture accidents

5、Easy to install

Large diameter ring pull design. Installation and operation more Convenient

Customized drop out fuse cutout

Technical information of drop out fuse cutout

NDRW12 series drop out fuse cutout 10-15KV

Rated voltage: 10-15KV

Rated current: 100A, 200A

Breaking current: 8/10 kA

Power frequency withstand voltage (kV): 40kV

Size (cm): 42 x 37 x 13.5

NDRW12 series drop out fuse cutout 15-24KV

Rated voltage: 15-24KV

Rated current: 100A, 200A

Breaking current: 10/12 kA

Power frequency withstand voltage (kV): 45kV

Size (cm): 52 x 37 x 13.5

NDRW12 series drop out fuse cutout 24-27KV

Rated voltage: 24-27KV

Rated current: 100A, 200A

Breaking current: 10/12 kA

Power frequency withstand voltage (kV): 45kV

Size (cm): 52 x 38 x 17

NDRW12 series drop out fuse cutout 33-36KV

Rated voltage: 33-36KV

Rated current: 100A, 200A

Breaking current: 10/12 kA

Power frequency withstand voltage (kV): 45kV

Size (cm): 62 x 38 x 17

The application of drop out fuse cutout

1、Protection of Transformers

Transformers are vital for adjusting voltage levels between high-voltage transmission lines and lower-voltage distribution lines. drop-out fuse cutout protect these transformers from currents exceeding their capacity, which can cause overheating and failure.

2、Line Protection

drop-out fuse cutouts safeguard distribution lines from overcurrents caused by faults like line-to-ground contacts or short circuits, ensuring a stable and reliable power supply.

3、Equipment Safety

Beyond transformers and lines, drop-out fuse cutouts are integral to protecting a variety of electrical equipment from overcurrent damage, thus ensuring longevity and reducing maintenance costs.

Precautions for drop out fuse cutout

1、Proper Sizing and Selection: Ensure correct sizing to match the system’s operating current and specific equipment protection needs.

2、Regular Inspections: Periodic checks for wear, damage, or contamination to maintain system integrity.

3、Safe Handling Practices: Only qualified personnel should handle high voltage fuses, using proper safety equipment and procedures.

4、Environmental Considerations: Installations should account for local conditions like temperature extremes and moisture to ensure reliable operation.

leave your question

Get your Comfortable Solution

GRL Electric Co., Ltd. is one of the leading companies in the Middle And High End market of low-voltage electric in China

Need Help With Finding The Right Technical Solution?
GET A QUOTE